Floor Loading Commercial Dumbwaiter with Fire Rated Doors

Product Details
Customization: Available
After-sales Service: 7*24 Hours Via Phone/Whatsapp/Email
Warranty: 18months
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
  • Floor Loading Commercial Dumbwaiter with Fire Rated Doors
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Options for Better Experience
  • Challenging Issues Encountered
  • Installation Instructions
  • Project Show
  • Get A Free Quote
Overview

Basic Info.

Model NO.
XYZD-FLFRD
Type
Wellhole and Derrick
Load Capacity
300kgs
Speed
0.40m/s
Drive Mode
AC
Open & Close Type
Manual
Lift Mechanism
Traction
Deceleration Device
With Deceleration Device
Guide Rail
T Guide
Elevator Door
Sider Door
Door Knife
Single
Attendant
With Attendant
Applicable Industries
Restaurant, Hotels, Warehouse, Bank, Childcenter
Certification
CE, ISO 9001
Local Installation Service
Yes
Free Spare Parts
Yes
Tailor-Made Service
Yes
Transport Package
Plywood Case
Specification
Packed in 5 plywood cases
Trademark
XYZLIFT
Origin
China
HS Code
842810
Production Capacity
1000 Units/Year

Product Description

Floor Loading Commercial Dumbwaiter with Fire Rated Doors

Product Description

Floor Loading Commercial Dumbwaiter with Fire Rated Doors

 

Introducing our Fire-Rated Commercial Elevator, specifically crafted with specialized materials to provide essential fire-resistance capabilities. This type of elevator is perfectly suited for industries requiring stringent safety measures against fire hazards.

Key Features:

  • Fire-Resistant Components: The elevator is equipped with several fire-resistant elements, including fire-rated door devices, fire-resistant door panels, fire-resistant door frames, and fireproof thresholds, ensuring comprehensive protection.
  • Compliance with EN81-58: Our fire-rated service elevator adheres strictly to the EN81-58 standard, which specifies the requirements for the fire resistance of elevator doors. This compliance ensures that the elevator meets European safety regulations and provides a high level of safety and reliability.
  • Suitable for Specialized Industries: Ideal for environments where fire safety is critically important, such as chemical plants, laboratories, and manufacturing facilities where fire risks are higher.

 

Product Parameters


MODEL

XYZD-FL2

lnstallation site size

1600*1600mm

Car size

1200*1200*1200mm

Door opening

Opposite opening

Doors

Bi-parting Stainless Steel. Fire-Rated Doors as below photo.

Floor height

3300mm

Pit depth

900mm

Speed

0.4m/s

Controls
Automatic push buttons, call & send. Complete with car position indicator, in use indicator, door open signal & Lift arrival buzzer

Customize service
The lifting height, cabin size, and door orientation can all be customized according to your specifications.

Please note: We can customize the lift's height, cabin dimensions, and door direction to meet your specific requirements.
 

Doors Certifications include:

  • 2014/33/EU: European Union directive for lift safety.
  • EN 81-20/50: Specifications for the safety of lifts in Europe.
  • EN 81-21: Adjustments for existing buildings.
  • EN 81-71: Available upon request, for vandal-resistant doors.
  • EN 81-72: Specifications for fire-fighter lifts.
  • EN 81-58: Standards for fire resistance of lift landing doors, including E, EI, and EW classifications.
  • DIN 18901: German standards for lift doors.
  • BS 476 Part 22 E CLAUSE 8 & 7: British standards for fire resistance.
  • GOST 53780/53871: Russian standards for lift components.
  • GOST 30247.3 E & EI: Russian standards for fire resistance.
  • Australia AS1735: Australian standard for lifts.
  • Australia AS1530: Australian standard for methods of fire tests on building materials.
  • Brazil NBR NM_20: Brazilian standard for lifts.
  • ASME A17.1: American standard for residential lifts.
  • Lloyd's Register: Compliance for maritime applications.

*Please note that certification depends on the specific configuration of the door.

Options for Better Experience

We recognize that every customer has specific requirements for Commercial Dumbwaiter Lift.
For example:

  1. If you're operating the dumbwaiter in colder settings, you might opt for a cabin equipped with thermal insulation.
  2. For enhanced efficiency in door operation: Consider a dumbwaiter featuring dual doors on a single floor level.
  3. For those seeking a touch of luxury, we offer the option of a fully copper-plated dumbwaiter.

Furthermore, to suit different installation site dimensions, we provide a variety of landing door options: Automatic landing doors, swing doors, and roller doors.

Floor Loading Commercial Dumbwaiter with Fire Rated Doors

Challenging Issues Encountered

Exceptional customization capabilities for Commercial Dumbwaiter
No matter what challenging issues you encounter: no pit, small hoistway, limited overhead space, or the need for highly stable marine dumbwaiters, our experienced technical team will provide you with satisfying solutions. Contact us to get a free quote and design.

Floor Loading Commercial Dumbwaiter with Fire Rated Doors

Installation Instructions


Every customer is concerned about the installation of the Floor Loading Type Commercial Dumbwaiterdumbwaiter. Each delivered dumbwaiter comes with an installation manual and installation video. Should you face any challenges during the installation process, our skilled technical team is committed to providing resolutions within 2 hours, ensuring a seamless and efficient setup.

Here are the 10 steps guide to install a Commercial Dumbwaiter:

Step 1: Connect Stand Columns and Shaft Beams

  • Lay out and secure stand columns and shaft beams on a level foundation.

Step 2: Connect Guide Rails

  • Attach guide rails inside shaft beams using brackets; ensure vertical alignment.

Step 3: Motor Installation

  • Install the motor at the top or in a motor room; connect to the drive system.

Step 4: Counterweight Installation

  • Set up counterweight frame, add weights, and connect to the cabin via pulley.

Step 5: Fix the Cabin and Guide Shoes

  • Lower cabin into shaft, align with guide rails, and attach guide shoes for smooth movement.

Step 6: Fix Cabin Door

  • Install and align the cabin door for proper operation.

Step 7: Fix Landing Doors

  • Install landing doors, ensuring alignment and secure locking.

Step 8: Buffers Installation

  • Place buffers at the shaft's bottom to absorb impacts.

Step 9: Fix Leveling Parts / Limited Switches

  • Install leveling devices and limit switches for precise stops and safety.

Step 10: Electric Controller

  • Set up the electrical controller for managing operations; ensure secure connections.

Each step is essential for safety and functionality. Refer to the manufacturer's manual for detailed instructions.

Project Show

Our commercial dumbwaiter is suitable for transporting food and miscellaneous items between floors.
Whether you operate in hotels, restaurants, pubs, clubs, music, theatre and performance venues, childcare centers, hospitals, or schools. Our dumbwaiters are also ideally suited for residential settings such as houses and villas, as well as financial, industrial, and logistical facilities like banks, factories, and warehouses. They are expertly designed to solve the transportation challenges between floors, enhancing efficiency and convenience across a diverse range of environments.
Our agents around the world can visit to measure and provide free plans.

Floor Loading Commercial Dumbwaiter with Fire Rated Doors

Get A Free Quote

Floor Loading Commercial Dumbwaiter with Fire Rated Doors
Custom Commercial Dumbwaiter
Tailored to Your Requirements


Receive an accurate dumbwaiter solution within 24 hours. Please provide the main details as follows:

1. Installation size/floor hole size/shaft size

2. Height of each floor (F1, F2, etc.)

3. Car door direction as below photo

4. Local voltage

 

Floor Loading Commercial Dumbwaiter with Fire Rated Doors
 

Based on over 10 years of sales experience, we have produced four loading configurations according to customer requirements. The first 2 configurations are the most common. Contact us to let us know which one suits your needs:

  • Single side
  • Opposite sides
  • Adjacent side
  • Three sides

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier